Q1 Power Transmission
- I=P/V=60000/2000=30 A. [2]
- Ploss=I2R=302(8.0)=7.2×103 W. [2]
- I=60000/20000=3.0 A; Ploss=3.02(8.0)=72 W. [3]
- For fixed transmitted power, higher voltage gives lower current; cable heating depends on I2, so losses fall greatly. [2]
- Heating in coil resistance; reduce with thick, low-resistance copper wires. [2]
- Circulating currents induced in the iron core; reduce using insulated laminations. [2]
- Energy lost in repeated magnetisation/demagnetisation; reduce using soft iron/low-hysteresis material. [2]
- Some input energy is dissipated in these losses and by flux leakage. [1]